Oxidation of Phenolic Wastewater by Fenton's Reagent
Abstract
Phenol oxidation by Fenton's reagent (H2O2 + Fe+2) in aqueous solution has been studied for the purpose of learning
more about the reactions involved and the extent of the oxidation process, under various operating conditions. An initial
phenol concentration of 100 mg/L was used as representative of a phenolic industrial wastewater. Working temperature
of 25C was tested, and initial pH was set at 5.6 . The H2O2 and the Fe+2 doses were varied in the range of
(H2O2/Fe+2/phenol = 3/0.25/1 to 5/0.5/1). Keeping the stirring speed of 200 rpm.
The results exhibit that the highest phenol conversion (100%) was obtained under (H2O/Fe+2/phenol ratio of 5/0.5/1)
at about 180 min. The study has indicated that Fenton's oxidation is first order with respect to the phenol concentration
and the rate constant K, was found to be 0.0325s-1 .
For papers published in IJCPE, authors and their institutions all have the same rights to reuse articles published in the journal in accordance with the journal by IJCPE is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. This permits users to copy, redistribute, remix, transmit and adapt the work provided the original work and source is appropriately cited. Please check the license for full license terms and attribution requirements.